Accura Beater Segment
For E.R.M./ B50 Fine Cleaner / L B 5/6 Flexiclean
|
Trial No. 1 |
|
Details |
Before ABS fitment |
After ABS fitment |
Improvements |
|
RIETER B 50 FINECLEANER |
|
30's CH mixing |
|
|
|
| |
|
|
Waste Study |
|
|
Waste % in Fine Cleaner |
1.16 |
0.537 |
0.61% |
Total Waste %
(blowroom +card+comber) |
23.44% |
22.86% |
0.58% |
|
AFIS Study |
|
Fine Cleaner |
|
|
input neps/gm |
201 |
114 |
|
|
output neps/gm |
271 |
142 |
|
|
Nep generation |
34.80% |
24.50% |
Improved by 10.32% |
| |
|
Comber sliver |
|
|
Neps/gm |
31 |
25 |
Improved |
| |
|
|
|
|
L.R. B 5/5 E.R.M. CLEANER |
|
|
30'S CH mixing |
|
|
|
| |
|
|
J 34 SG 100% |
|
|
|
|
Trash 4.6%-4.9%. Mic4.6 |
|
|
|
| |
|
|
Waste Study |
|
|
Waste% in E.R.M. |
0.71% |
0.22% |
0.49% |
|
Cleaning Efficiency |
10% |
14.91% |
4.90% |
|
AFIS Study |
|
|
ERM |
|
|
|
|
input neps/gm |
316 |
300 |
|
|
output neps/gm |
347 |
327 |
|
|
Nep generation |
9.81% |
9.00% |
Improved by 0.81% |
|
scn/gm |
37 |
31 |
Improved |
|
scn size |
1184 |
1142 |
Improved |
|
|
|
Trial No. 2 |
|
Details |
Before ABS fitment |
After ABS fitment |
Improvements |
|
L.R. B 5/5 E.R.M. CLEANER |
|
60's CO mixing |
|
|
|
|
Yarn Studies |
|
|
50's CF |
|
Total imperfections
(-50%, +50% + 200%) |
235 |
219 |
6.80% |
Extra sensitivity
(-40%, +35%, +140%) |
1513 |
1459 |
3.56% |
|
C.S.P. |
2884 |
2939 |
Improved |
| |
|
60's CU |
|
Total imperfections
(-50%, +50% + 200%) |
485 |
429 |
11.54% |
Extra sensitivity
(-40%, +35%, +140%) |
2684 |
2460 |
8.34% |
|
C.S.P. |
2777 |
2821 |
Improved |
|
|
|
Trial No. 3 |
|
Details |
Before ABS fitment |
After ABS fitment |
Improvements |
|
L B 5/6 FLEXICLEAN |
|
20's Mixing |
|
|
|
S.L. - 23MM, Mic - 3.3 - 4.4
Trash < 3.5% |
|
|
|
|
Waste Study |
|
|
Waste % in Flexiclean |
0.34% |
0.07% |
0.27% |
|
Cleaning
effeciency |
8.20% |
11.53% |
3.33% |
|
|
|
|
Yarn Study |
|
Total Imperfection
(-50%, +50%, +200%) |
183 |
119 |
34.90% |
|
R.K.M. |
15.11 |
16.54 |
Improved |
|
Classimat faults |
|
|
Total faults |
199.5 |
98.5 |
50.60% |
|
Objectionable
faults |
3.6 |
2.4 |
Improved |
| |
|
L.R. B 5/5 E.R.M. CLEANER |
|
|
24's KW Mixing |
|
|
|
|
E.R.M. Waste Study |
1.10% |
0.28% |
0.73% |
|
Trash% in waste |
56.16% |
86.76 % |
More trash extraction |
|
Lint% in waste |
43.04% |
8.36% |
Saving of usable lint |
| |
|
|
|
|
Yarn Studies |
|
|
|
|
Total I.P.I. (-50%, +50%, +200%) |
348 |
278 |
20% |
|
Total I.P.I - Higher Sensitivity |
2895 |
2582 |
10.80% |
|
R.K.M. |
15.61 |
15.91 |
Improved |
|
Hairness |
6.42 |
6.28 |
Improved |
|
|
|
|